11121 West California Ave.
Youngtown, AZ 85363
623-444-6988

Our Top Cities


Local Reviews
for sun city, az

Rated 5.0 out of 5 stars based on 8 customer reviews

Always reliable.

Have used Canyon since moving here in 2011. Very good service and great people working there.

  • Overall Experience
  • Friendliness
  • Quality
  • Professionalism

Wonderful!

Such a wonderful experience! They showed up on time and were very nice to deal with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Friendly service man

Thorough job on inspecting the air conditioner. The service man was very professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service!

Was very pleased

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good job

Awesome professional company

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Jose was very professional and thorough. A pleasant experience. I will be using Grand Canyon from now on.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome

wonderful, honest job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great experience!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for sun city, az

Troy V.

Troy V. Job Checkin

Completed a repair on a Ruud air conditioner system. The customer was experiencing issues with the cooling and airflow. After inspecting the system, found that the air filter was dirty and clogged. After replacing the air filter, I tested the system to ensure proper operation. The customer was pleased with the results.


Troy V.

Troy V. Job Checkin

Conducted complimentary summer tune-up on a Carrier 25HBC5 air-source heat pump. Tested refrigerant pressures and temperatures - system proved adequately charged. Cleaned outdoor coil fins and fan blades. Lubricated both indoor and outdoor fan motors. Inspected ductwork for leaks and airflow obstructions. Cycled unit through cooling mode to verify proper operation. Heat pump now operating efficiently for peak cooling performance.


Troy V.

Troy V. Job Checkin

Responded to a service call for an aging Goettl air conditioning package unit experiencing electrical faults. Upon arrival, tested control board voltages which indicated a failed run capacitor. Replaced dual-rated capacitor matched to specified MFD and voltage ratings. Still encountering lockout codes, so I megged motor windings for shorts and grounds - compressor windings tested within acceptable ranges. Cycled through cooling mode and monitored live current draws to ensure proper amp loads. Located and repaired a loose wire connection on the 24V transformer which was causing intermittent voltage drop. System now maintaining setpoint temperature with all safety circuits operational.


Troy V.

Troy V. Job Checkin

Today, I tackled a noisy York air conditioner in Sun City, AZ, that was emitting an unusual squealing sound. I started by inspecting the blower motor and fan belt, which can often be the culprits of such noises. After tightening the belt and lubricating the motor bearings, the squealing was significantly reduced. I also checked the condenser unit for any loose parts or debris that might be causing vibration. After securing all components and ensuring the system was clean, the unit ran quietly, restoring peace and efficient cooling to the home.


Troy V.

Troy V. Job Checkin

Conducted refrigerant leak detection on a Goodman GSC160481 air conditioning system in Sun City, AZ. Used an electronic refrigerant sniffer to pinpoint general leak area around the condenser unit. Employed nitrogen trace gas testing along with soap bubble solution to isolate the specific leak location at the process tube joining the reversing valve. Prepped the area then brazed a copper saddle tap valve into the line set. Pulled a vacuum and weighed in the proper R-410A charge. Ran the system through multiple cooling cycles to verify repair, monitoring superheat and subcooling values within specifications. Leak sealed, airflow restored, and cooling capacity recovered.


Troy V.

Troy V. Job Checkin

this morning in Sun City, I conducted summer maintenance on a Carrier air conditioner, ensuring it’s ready for the hot months ahead. I started by checking refrigerant levels for optimal cooling efficiency and cleaned the condenser coils to prevent overheating. I also inspected and tightened electrical connections to enhance system reliability. The air filters were replaced to improve airflow and air quality. The unit is now fully prepped to deliver consistent, efficient cooling.


Troy V.

Troy V. Job Checkin

Performed annual preventive maintenance service in Sun City on a Westinghouse 3-ton split system air conditioning unit. Initiated deep vacuum to remove moisture and non-condensable gases from the refrigeration system. Replaced liquid line filter drier to prevent acid buildup. Flushed indoor evaporator coil using eco-friendly condenser cleaner and rinsed with pressurized water stream. Inspected blower assembly, lubricated motor bearings, and verified proper rpm. Checked refrigerant charge via superheat calculation, adjusted to 12°F superheat value. Air filters replaced and thermostat calibration verified. Unit is now operating within Westinghouse's specified temperature split range and energy efficiency parameters for the cooling season.


Troy V.

Troy V. Job Checkin

Conducted comprehensive tune-up service on an American Standard 4A7A6060K1000AA air conditioning system. Began by measuring temperature drop across evaporator coil - 20°F split indicated adequate airflow. Used refrigerant gauges to check system operating pressures and temperatures. Ran system through cooling cycle while logging subcooling and superheat values which were within specs. Completed thorough coil cleaning using foaming cleaner and flush. Inspected all electrical components - ran capacitor and contactors checked good. Replaced air filter and treated indoor blower components with antimicrobial mist. System is now running at peak energy efficiency for the summer season.


Troy V.

Troy V. Job Checkin

This morning in Sun City, I performed spring maintenance on a Lennox air conditioner. I checked the refrigerant levels for optimal cooling, cleaned the condenser coils to increase efficiency, and tightened all electrical connections for safety. I replaced the air filters to ensure clean airflow throughout the system. The unit is now fully tuned up for the upcoming warmer months.


Troy V.

Troy V. Job Checkin

Responded to a service call for an Amana ASX16 air conditioning system in cooling distress. Upon arrival, attached gauges to monitor system pressures and temperatures. Noticed high head pressure coupled with high subcooling value, indicating a potential restriction. Inspected the liquid line filter drier which was severely clogged. Replaced the drier core and evacuated the lineset before recharging to factory specifications with R-410A refrigerant. Ensured proper airflow across the indoor evaporator coil by treating it with a foaming coil cleaner. Cycled the system through cooling mode, confirming discharge superheat landed within 20-30°F range. Amana unit is now operating within manufacturer's guidelines, delivering rated cooling capacity.


Troy V.

Troy V. Job Checkin

working on a Trane air conditioner


Troy V.

Troy V. Job Checkin

ac repair on a Carrier Air Conditioner


Troy V.

Troy V. Job Checkin

Ac repair on a Heil air conditioner. Upon completion, the system was ran to ensure it was cooling properly again. The customer was thankful for the service.


Troy V.

Troy V. Job Checkin

Maintenance on a Trane ac unit. The system was thoroughly inspected for any signs of wear and tear. Outside of the filter being replaced, the air conditioning unit is running well for the home.


Josh S.

Josh S. Job Checkin

AC repair on a Trane ac unit.